HP e3000 MPE/iX Release 6.5 System Software Maintenance Manual (30216-90325)

460 AppendixH
Error Messages and Warnings
Stage/iX Messages (STAGEMAN)
you need assistance.
1099 Message Encountered an unexpected error: Subsys =
value
,
Info =
value
Cause STAGEMAN encountered an error that is not recognized
by the HP Stage/iX facility, and has no matching error
message in the system catalog. This normally indicates a
problem within the HP Stage/iX subsystem that should be
reported to Hewlett-Packard.
Action Contact your Hewlett-Packard Response Center for
assistance.
Message 1100 and 1101 not used.
1102 Message Attempted to add more than the maximum number of
staging areas
allowed. (Max = ) (STAGEMAN 1102)
Cause The maximum number of staging areas supported by the
HP Stage/iX facility has been reached, so STAGEMAN
cannot add another staging area.
Action Delete one or more existing staging areas to make room,
and re- execute the command.
1103 Message File “
name
” does not exist in
the Base. (STAGEMAN 1103)
Cause The file was staged with a file disposition of either
REPLACE or DELETE, which tells STAGEMAN that a
version of the file should exist in the Base. STAGEMAN
reports this warning when it cannot find the file in the
Base at validation time.
Action None
1104 Message ADD file “
name
” exists in the Base.
(STAGEMAN 1104)
Cause The file was staged with a file disposition of ADD, which
tells STAGEMAN that no version of the file should exist in
the Base. STAGEMAN reports this warning when it finds
the file in the Base at validation time.
Action None
1105 Message Failed to find the staging area in the Globals
file. (STAGEMAN 1105)
Cause STAGEMAN failed to find an entry for the staging area in
the HP Stage/iX Globals file when it expected to find one.
This indicates a problem with the HP Stage/iX facility, and
should be reported to Hewlett-Packard.
Action Contact you Hewlett-Packard Response Center for
assistance.