Error Messages and Warnings
Installer Error Messages (INSTERR)
Contact the Response Center if further assistance is
required.
69 Message Copy of SPLINTR.PUB.SYS to SPLINTR.INSTALL.SYS
failed.
(INSTERR #69)
Cause The installer was attempting to copy SPLINTR.PUB.SYS
to SPLINTR.INSTALL.SYS.
Action Examine file SPLINTR.INSTALL.SYS for accessors
other than the installer.
If file is being accessed, free up file.
Check for free disk space to copy file, and if needed free
up disk space. There are two methods for obtaining
additional disk space:
Use the ALTERVOL command in VOLUTIL to set the
permanent and transient space allocation
assignments to 100% on all system volumes except
LDEV 1.
Store user files to tape and them purge them.
Restore the files from tape at the end of the
installation.
Take appropriate corrective measures and run the
installer again.
Contact the Response Center if further assistance is
required.
70 Message A call to the LINKEDITOR by the installer failed.
(INSTERR #70)
Cause The link editor variables LKEDSTAT and/or LKEDCMD
were checked after a call to the link editor by the installer.
The variables were found to contain error values.
Action Record the error messages preceding this message.
Print file AUTOLOG.INSTALL.SYS to view detailed
error from link editor.
Check error message cause and action in the HP Link
Editor/iX Reference Manual.
Take appropriate corrective measures and run the
installer again.
Contact the Response Center if further assistance is
required.
71 Message The installer failed to purge TEMPNL when
patching
the OS SOM. (INSTERR #71)