HP e3000 MPE/iX Release 6.5 System Software Maintenance Manual (30216-90325)

Appendix G 319
HP Stage/iX Reference
HP Stage/iX Commands
STAGEMAN> errmsg 1170
MESSAGE:
The HP Stage/iX Globals file is temporarily in use by another process. Can't
complete
command. (STAGEMAN 1170)
CAUSE:
STAGEMAN could not open the HP Stage/iX Globals file because it was held open
exclusively by another process at the time. The other process was most likely
STAGEMAN
(or HP Patch/iX) being run in another job or session (STAGEMAN always opens
the
Globals file for exclusive access).
ACTION:
Either terminate the additional STAGEMAN process, or allow the command being
executed
by that process to complete.
EXIT
The EXIT command (abbreviated E or EX) exits the STAGEMAN utility. You must have System
Manager (SM) or System Operator (OP) capability to execute this command.
Syntax
EXIT
Parameters
(none)
Example
To exit from STAGEMAN, enter:
STAGEMAN> EXIT
EXPERT
The EXPERT command is used to put STAGEMAN into expert mode. There are several
STAGEMAN commands that extend the basic STAGEMAN functionality which require you to be
in EXPERT mode. All expert mode commands require SM capability. The EXPERT command
itself requires SM capability to execute.