HP e3000 MPE/iX Release 6.5 System Software Maintenance Manual (30216-90325)
246 AppendixD
Backdating Your System
Finishing Up
used to create the backup.
Then proceed to Step2.
2. Run the NMMGRVER conversion utility.
:RUN NMMGRVER.PUB.SYS
3. Enter NMCONFIG.PUB.SYS at the prompt:
FILESET TO BE SCANNED? NMCONFIG.PUB.SYS
OK TO CONVERT NMCONFIG? Y
• If the return message is no
need to convert, proceed to “Restart System Functions.”
• If the return message is conversion completed
successfully, then AUTOINST has converted your configuration file and it needs to
be cross validated with sysgen information. Proceed to “Cross Validate.”
Cross Validate
Perform the steps in this section if you did either of the following:
• Completed the previous section, “Convert Data Communications,” and your files were
converted.
• Created a new NMCONFIG file using nmmgr.
If the SYSGEN command, RDCC, was used previously, the network configuration file that was
specified in that command is written to the CSLT that AUTOINST created. If this CSLT is
used as a backup tape for a reinstallation, then the datacomm configuration file that will
be restored will require conversion using the NMMGRVER.PUB.SYS utility after the
installation.
To validate data communication files:
1. Run NMMGR.PUB.SYS
:NMMGR
2. Open the configuration file using the [F1] key.
3. Modify the configuration file, if required.
If you need to add, delete, or change any item in the configuration file, do so now. For
example, now is the time to add a DTC or change a UPS configuration.
If you copied and updated your NMCONFIG file from another system, you must update the
network addresses and other devices for this system.
a. If you have a PC-based network management configuration, follow the installation
and configuration procedures described in the Using the OpenView DTC Manager
Manual.
b. For information on NMMGR, refer to Using the Node Management Services (NM S)
Utilities.
c. For information on configuring UPS devices, refer to Performing System
Management Tasks.