HP e3000 MPE/iX Release 6.5 System Software Maintenance Manual (30216-90325)
Chapter 7 179
Support Tools Manager (STM) for MPE/iX
Remote Execution
Started: Tue Sep 28 08:31:05 1999
Failed: Tue Sep 28 08:31:05 1999
A UNIT ATTENTION was received as a result of the SCSI Read Capacity
command. This is not necessarily an error, but indicates the device was
undergoing built-in test or was previously reset.
Possible Causes(s)/Recommended Action(s):
The disk drive has been reset or the Mode Select parameters have
been changed.
Rerun the information module.
If a test result is anything other than Successful or Failure, look at the Test Activity Log
for the device. For example, if a test results in a Incomplete status, the Test Activity Log
will explain whether the problems is due to missing device files or other possible errors.
Other logs are available with a record of STM system events (for example, a User Interface
Log).
Remote Execution
You can run the STM user interface on one machine, and use it to run support tools on one
or more remote machines. See Figure 7-7. for a display of possible connections.
The computer running the user interface is the UI system and the computer running the
support tools is the Unit Under Test or UUT).
As always you can run the user interface and support tools on the same machine. In this
case the UI machine and the UUT are one and the same.