HP e3000 MPE/iX Release 6.0 System Software Maintenance Manual (30216-90272)

444 AppendixH
Error Messages and Warnings
Stage/iX Messages (STAGEMAN)
Action Report this problem to your Hewlett-Packard Response
Center.
1310 Message Error in accessing message catalog. (STAGEMAN
1310)
Cause STAGEMAN could not access its message catalog file,
STAGE000.PUB.SYS.
Action Make sure the catalog file exists and is not opened
exclusively by another process.
1311 Message Invalid numeric index into command history
stack. (STAGEMAN 1311)
Cause The user has specified a value for the DO or REDO command
which does not match a corresponding value in the
command history stack.
Action None
1312 Message Command name length exceeds 16 characters.
(STAGEMAN 1312)
Cause The length of the command name specified by the user is
greater than the maximum command length allowed by
STAGEMAN (currently 16 characters).
Action None
1313 Message Insufficient capabilities to execute this
command. (STAGEMAN 1313)
Cause In order to execute commands which modify the HP
Stage/iX environment, STAGEMAN requires users to have
System Manager (SM) capability. To execute “read only”
commands (LIST, for example) the user must have at least
System Operator (OP) capability. This error indicates that
one or both of these rules have been broken.
Action Alter the user to have the required capability, or run
STAGEMAN under another user.
Message 1314-1317 not used.
1318 Message Command only valid in interactive mode.
(STAGEMAN 1318)
Cause The command was issued in batch mode (in a file specified
by USE, for example), but is only appropriate in
interactive mode.
Action Execute the command in interactive mode.
1319 Message 1319 not used.
1320 Message Invalid command edit operation. (STAGEMAN 1320)
Cause STAGEMAN is confused by the command edit operation