392 AppendixH
Error Messages and Warnings
Installer Error Messages (INSTERR)
corrupt.
Action • Document any error message text prior to the error.
• Use SHOWVAR MPE_TARG_VUF to check the status
of the variable.
• Print the INITCIVR.INSTALL. There should be a line
with a SETVAR command for the indicated variable. If
the line does exist, execute INITCIVR and run
HPINSTAL again.
• If INITCIVR.INSTALL.SYS does not exist or does not
contain the SETVAR command for the listed CI variable,
VSCLOSE both CD-ROM volumes and follow the setup
procedures in the HPINSTAL manual. Run HPINSTAL
from the start.
188 Message Encountered an error building the file TARGVUF.
(INSTERR #188)
Cause The installer was attempting to build the file TARGVUF.
Action • Document any error message text prior to the error.
• If old TARGVUF exists, purge it.
• Check for enough free disk space to build files. There
are two methods for obtaining additional disk space:
— Use the ALTERVOL command in VOLUTIL to set the
permanent and transient space allocation
assignments to 100% on all system volumes except
LDEV 1.
— Store user files to tape and them purge them.
Restore the files from tape at the end of the
installation.
• Take appropriate corrective measures and run the
installer again.
• Contact the Response Center if further assistance is
required.
189 Message Error encountered purging the file SYSGLOG.
(INSTERR #189)
Cause The installer was attempting to purge the log file
SYSGLOG.
Action • Document any error message text prior to the error.
• Examine file for accessors other than the installer.
• If file is being accessed, free up file.
• Take appropriate corrective measures and run the
installer again.