- A

366 AppendixH
Error Messages and Warnings
Installer Error Messages (INSTERR)
command to determine which USER file equations can
be RESET. RESET any USER file equations.
Take appropriate corrective measures and run the
installer again. The installer will reissue any needed
file equations.
• HPPATH variable is a non-standard path. Issue the
following command:
:SETVAR HPPATH !HPGROUP,PUB,PUB.SYS
Take appropriate corrective measures and run the
installer again. The installer will reissue any needed
file equations.
• Contact the Response Center if further assistance is
required.
89 Message Error while issuing file equation for the NL
library. (INSTERR #89)
Cause The installer attempted to issue the file equation:
:FILE NL.PUB.SYS=NL
(NL being in the local group INSTALL.SYS), prior to
calling SYSGEN to create the CSLT.
Action • FILE Command Table is possibly full. Do a LISTEQ
command to determine which USER file equations can
be RESET. RESET any USER file equations.
• Take appropriate corrective measures and run the
installer again. The installer will reissue any needed
file equations.
• Contact the Response Center if further assistance is
required.
90 Message Error while issuing file equation for the XL
library. (INSTERR #90)
Cause The installer attempted to issue the file equation:
:FILE XL.PUB.SYS=XL
(XL being in the local group INSTALL.SYS), prior to
calling SYSGEN to create the CSLT.
Action • FILE Command Table is possibly full. Do a LISTEQ
command to determine which USER file equations can
be RESET. RESET any USER file equations.
• Take appropriate corrective measures and run the
installer again. The installer will reissue any needed
file equations.
• Contact the Response Center if further assistance is