- A

Appendix H 339
Error Messages and Warnings
Installer Error Messages (INSTERR)
• Corrupt files - Manually RESTORE the corrupt files
from the PowerPatch tape. If successful, this indicates
there were transmission errors.
• Take appropriate corrective measures, and run the
installer again.
• Contact the Response Center if further assistance is
required.
8 Message Add-on cannot be done without an ADD-ON tape.
(INSTERR #8)
Cause Occurs in AUTOINST only: AUTOINST received a
negative response to the query about a SUBSYS tape in
the installation package while performing the ADD-ON
option.
Action • Do not select the ADD-ON option unless there is a
SUBSYS tape in the installation package.
• Respond with YES to the SUBSYS tape query if there
is a SUBSYS tape in the installation package.
9 Message SUPACCT has been purged from system. (INSTERR
#9)
Cause The installer could not find SUPACCT.PUB.SYS.
Action • Restore @ACCT.PUB.SYS from the FOS tape. Be sure
to use the appropriate FOS tape.
• Run the installer again after restoring the file.
• Contact the Response Center if further assistance is
required.
10 Message STREAMS device not enabled. The installer cannot
continue. (INSTERR #10)
Cause The installer could not obtain the LDEV number for the
STREAMS device.
Action • Ensure that a STREAMS device is configured and is
enabled.
• The STREAMS device no longer needs to be LDEV 10.
• Take appropriate corrective measures, and run the
installer again.
• Contact the Response Center if further assistance is
required.
NOTE
INSTERR #12 applies only to AUTOINST, not HPINSTAL.
11 Message 11 Not used