HP e3000 MPE/iX Release 6.0 System Software Maintenance Manual (30216-90272)
Table Of Contents
- Preface
- 1 Introduction
- 2 Task Checklists
- 3 Planning for Your Task
- 4 Preparing Your System
- 5 Modifying Your System
- 6 Finishing the Process
- A Manually Installed Products
- B Configuration Tables
- C Managing Disk Space
- D Backdating Your System
- E CD-ROM Resources
- F HP Patch/iX Reference
- G HP Stage/iX Reference
- H Error Messages and Warnings
- A

Chapter 5 113
Modifying Your System
5.7 Creating the CSLT Using AUTOINST
5.7 Creating the CSLT Using AUTOINST
AUTOINST sets up the necessary environment, restores files, and creates the accounting
structure for the installation.
To create the CSLT using AUTOINST:
1. From the console, log on and reset system utilities.
:HELLO MANAGER.SYS,INSTALL;HIPRI
:SPOOLER LP;OPENQ
:STREAMs streams_device
A common streams_device value is 10. An LP device must be configured in SYSGEN.
Already spooled and streamed messages might display.
Reset the outfence.
:OUTFENCE 14
Confirm that INSTALL.SYS has no limit on file size.
:REPORT INSTALL.SYS
2. If you are applying PowerPatch patches, go to Step 3.
If you are not applying PowerPatch patches, go to Step 4.
PowerPatch Tasks
3. Restore PowerPatch files.
AUTOINST requires the AUTOINST fileset, its dependencies, and files from the
PowerPatch tape to determine which patches qualify for your system.
a. Mount the PowerPatch tape and put the tape drive online.
:FILE PPT;DEV=TAPE
b. Restore the files.
:RUN STORE.PUB.SYS;INFO="RESTORE *PPT;A@,F@;SHOW;DEV=1"
c. Reply to tape request.
d. When the files are restored, dismount the PowerPatch tape.
e. Go to Step 4.
4. Run AUTOINST.
:RUN AUTOINST.INSTALL.SYS
5. If you receive a missing capabilities message, use ALTGROUP to add capabilities to the
INSTALL group.
:ALTGROUPINSTALL;CAP=BA,IA,PM,MR,DS,PH
Run AUTOINST again.
6. The update tool checks for disk space. If you receive an error message: