HP Data Entry and Forms Management System (VPLUS) Reference Manual (32209-90024)
556 AppendixB
VPLUS Error Messages
REFSPEC Messages
621
Expected "F", "V", or "U" in
record format field.
Enter one of the listed codes in the Output
Record Format box of the GLOBALS menu;
default is F (fixed length).
622
Record size must be a numeric
value less than 32767.
Enter a positive integer lessthan 32767 in the
Record Length box of the GLOBALS menu, or
leave the default length of 80 characters.
624
Expected literal, system
constant or ASCII equivalent in
string.
Record terminator or field separator string
can only be a quoted string, the numeric
equivalent of an ASCII c.haracter preceded by
$, or a system constant: $LF, $CR, $GS, $US,
or $RS.
625
Output field must be expanded
to allow for checkdigit.
If you enter 10 or 11 in the CDIGIT box of the
OUTPUT FIELD menu, be sure to increase
the size of the output field on the OUTPUT
RECORD menu.
626
Internal error: Checkdigit
option not valid for data type.
See error 610
627
Strip fields must start and end
with a quote.
Enclose any characters in a STRIP box of the
OUTPUT FIELD menu between quotes.
628
Use "" or ’’ to indicate " or ’
inside a literal.
Use double quotes for any quotation marks
within a literal (literal is entered in the
GLOBALS menu.)
629
Plus option cannot be "Y" if
sign option is "N".
If you want a plus sign, you must also specify
where you want any sign in the SIGN box of
the OUTPUT FIELD menu.
630
Fill all has already filled
leading blanks.
Enter a character in Fill ALL OR Fill
Leading, not both.
631
Fill all has already filled
leading blanks.
Enter a character in Fill ALL OR Fill
Leading, not both.
632
IMPn can have digits only from
"0" to "9".
Number of implied decimal places must be a
digit.
Errors Message Cause/Action