HP Data Entry and Forms Management System (VPLUS) Reference Manual (32209-90024)
Appendix B 555
VPLUS Error Messages
REFSPEC Messages
Menu Processing Utility Errors
Errors Message Cause/Action
600
NUMn can have digits only from
"O" to "9".
A value other than a digit was entered for a
NUMn type field; change the data type or the
selection.
606
Must be NUMn, DIG, IMPn,MDY,
DMY, YMD, or CHAR.
Enter one of the listed codes as the data type
of this field; n can be a digit 0-9 for NUM, 1-9
for IMP.
608
Justify field must be "L", "R",
"C", or " ".
Enter one of the codes to justify field Left,
Right, or Center; default is Right justify for
numbers or dates, no justification for
characters.
609
Checkdigit must be either "10"
or "11".
If you want to insert a check digit, specify 10
for modulus 10, 11 for modulus 11.
610
Checkdigit can only be added to
fields of type DIGIT or CHAR.
If you want to add a checkdigit, change the
data type on the OUTPUT FIELD menu.
611
Internal error: Substring start
column value could not be
displayed.
Intrinsic ASCII failed.
612
Numeric fields cannot be
converted to fields of date
type.
When the input field is a number, you cannot
specify a data type of MDY, DMY, or YMD on
the OUTPUT FIELD menu. Change the data
type.
613
Date fields cannot be converted
to fields of numeric type.
When the input field is a date, you cannot
specify DIG, IMPn, or NUMn as the data type
on an OUTPUT FIELD menu. Change the
data type to a date or CHAR.
614
Fields of type CHAR cannot be
converted to other data types.
When the input field is type CHAR, you
cannot change the data type on an OUTPUT
FIELD menu. Leave the type as CHAR.
615
Internal error: Input length
value could not be displayed.
Intrinsic ASCII failed.
617
Only fields of type NUM, NUMn
and IMP can be signed.
If the input field is not one of the listed types,
you cannot specify a sign on the OUTPUT
FIELD menu.
618
Sign must be "L", "R","F", "Z",
"N" or " ".
Only the listed codes or a spacecan be entered
on the SIGN box of the OUTPUT FIELD
menu. Correct your entry.
620
Plus field must be "Y"or"N".
If you want the plus sign retained in the field,
enter Y in the PLUS SIGN? box; if N or blank,
only minus signs are inserted.