HP Data Entry and Forms Management System (VPLUS) Reference Manual (32209-90024)

534 AppendixB
VPLUS Error Messages
VPLUS Intrinsic Error Messages
VSHOWFORM Messages
VREADFIELDS Messages
Error Message Cause/Action
130
Internal Error: Terminal write
failed. (FSERR !)
FWRITE intrinsic failed.
131
Internal error: Color
conversion failed.
Error Message Cause/Action
150
The supplied read buffer (dbuf)
is too small.
The data buffer in memory is too small for the
data on the form. Check application program
DBUF array size and DBUFLEN.
151
Internal error: An expected DC2
from the terminal was missing.
Block mode or data comm problem. Press
REFRESH.
152
Internal error: A read
terminator (an RS or a GS) was
expected.
Press ENTER again. Also try REFRESH. If
problem recurs, check DBUFLEN in
application program. Possible block mode or
data comm problem.
153
A status request was pending,
so the terminal read was
invalid.
Application program requested terminal
status, then called VREADFIELDS.
154
An unrecognized escape sequence
was read.
Possible softkey problem. Press REFRESH or
perhaps RESET to correct.
155
Read length error.
Length of data actually read is less than
expected for current form.
160
Internal error: Terminal Read
Failed (FSERR!)
FREAD intrinsic failed. If user timeouts were
enabled in the user application, a time out has
occurred.
161
Field too long for HP3075/6
terminals.
The maximum length of a field on the HP
3075/6 terminals is 200 characters.
162
Terminal Power Failure
detected.
A power failure has been detected on an HP
3075/6 terminal.
163
Invalid error light.
Valid error lights are letters of the alphabet or
the @@ character.
164
HP3075/6 Terminal printer is
out of paper.
Load the printer with a roll of paper.
165
Device is not supported by
VPRINTLOCAL.
The terminal must be an HP 3075A or HP
3076A.
166
HP3075/6 Terminal does not have
a printer.
Your terminal is not equipped with a printer.