HP Data Entry and Forms Management System (VPLUS) Reference Manual (32209-90024)
Appendix B 523
VPLUS Error Messages
VPLUS Intrinsic Error Messages
015
Terminal type incorrectly
determined.
Possible block mode or data comm problem.
Check straps. Note: 2645 multipoint straps
should never be touched!
016
Internal error HP2645A
multipoint terminal mode not
correctly set.
See error 015.
017
Comarea too short for run-time
HP3075/6 terminals.
The Comarea must be 85 words for HP 3075/6
terminals. Set terminals. Comarealen to 85.
018
Non-page/block mode terminal
types not supported.
Redeļ¬ne terminal type. (Note: VPLUS
requires a terminal which supports page/block
mode.)
019
Internal error: FDEVICECONTROL
should not return ccg.
See System Manager.
021
Invalid terminal type.
TERMTYPE used is a printer terminal type
Error Message Cause/Action