HP Data Entry and Forms Management System (VPLUS) Reference Manual (32209-90024)

Appendix B 517
VPLUS Error Messages
FORMSPEC Error Messages
ARB Compile Errors
More Menu Init and Processing Errors
Error Message Cause/Action
3500
In ARB !, field ! has no
corresponding screen field.
Either delete the ARB field, or add a field to the
associated screen.
3501
In ARB !, field ! has an
incorrect length.
Change the ARB field length to match the
length of the corresponding screen field.
3502
In ARB !, field ! has an
incorrect ARB type.
Check the permitted conversion types and
correct the ARB data type.
3503
Internal error: IN ARB
!,missing source record for
field !.
Errors Message Cause/Action
7001
Correct syntax is: "Field
formname fieldtag/name", then
menu specs.
7002
Unable to open screen file.
7003
WARNING: No new screenfile
specified. Old screenfile was
closed.
7004
Correct syntax is: "ADD
formname [\comments]".
7005
Correct syntax is: "READD
formname [new formname]
[\comments]"
7006
A screen layout file is not
currently open.
7007
End of file when reading screen
layout file.
7008
File system error when reading
screen layout file.
7009
Form name in screen file record
not equal to current form name.
7010
Cannot find screen record for
form.
7011
Cannot find screen record for
form.
7012
Write of screen record to
screen layout file failed.