HP Data Entry and Forms Management System (VPLUS) Reference Manual (32209-90024)

Chapter 3 105
INTRODUCTION TO FORMS DESIGN
GLOBALS MENU
Window Enhancement
The window line is normally enhanced with inverse video, half bright. If
you want a different enhancement for this line, you must specify it in this
box. You may enter any of the standard enhancement codes (I, H, U, B,
S, and 1-8) in any combination, or you can specify no enhancements by
entering NONE.
Default Inverse video, Half bright (HI).
Define Function Key Labels
To define function key labels, enter Y to obtain the Global Function Key
Labels Menu. If you wish to retain the default global labels, leave this box
blank. When function key labels have been defined, FORMSPEC will place
an X in the Define Function Key Labels field. Once function key labels
have been defined, the default labels can be reset by entering an N in this
field. If you specify a Y in this field, the Global Function Key Labels Menu
is displayed, as shown in Figure 3-23.The data capture devices do not
support function key labeling.
Define Data Conversions
To use the ARB feature, you must specify default conversions for screen
data to application data and vice versa. Type Y in this field to reach the
Data Type Conversions Menu, shown in Figure 3-27. The default data type
conversions must be set up before you can create an ARB for a form.