Configuring Systems for Terminals, Printers, and Other Serial Devices (32022-90051)

Chapter 7 137
Terminal and Printer Profiles
Printer Switching Configuration Screen
port configuration remains unchanged when binary
mode is selected. If set to N, then the data length is set
to 8 and parity is set to none when binary mode is
selected. The default is N. Supported on
DTC 16iX/DTC 16MX and DTC 72MX only.
Default
destination This field specifies the system to which the printer is
dedicated if “Dedicated printer” is enabled, or to
which the printer will connect when automatic
connection is enabled. The field is required if
“Dedicated Printer” is set to Y or if “Automatic
Conneciton” is set to Y. Field can be a node name in
the format name.domain.organization or an IP address
in the format xxx.xxx.xxx.xxx. Default is the entry
in the field “Local HP 3000 node name” on the
Main screen.
Initialization
string Optional field that specifies the string that will be sent
to the attached device under one of the following
circumstances:
After resetting a port.
After the port is closed at the end of the spool file.
After establishing a connection to the DTC user
interface for modem connections when all modem
signals are up.
Field is case-sensitive and can be up to 16 characters,
including special characters and escape-code sequences
in the format ˆchar.