Communicator e3000 MPE/iX Release 6.5 (Non-Platform Software Release C.65.00 (30216-90291)

Chapter 4 113
Data Center Management
HP SureStore E Disk Array 12H on the HP 3000
HP SureStore E Disk Array 12H on the HP 3000
Rich Bassett
Walt McCullough
Commercial Systems Division
Site, Software and Hardware Requirements
The following is a summary of Site, Software and Hardware requirements for support of
the HP SureStore E Disk Array 12H.
Device installation and support is to be provided by HP. For detailed information on the
support and configuration of the Model 12H AutoRAID, field support personnel should
consult the updated version of the following documents:
HP SureStore E Disk Array 12H -- System Administrators Guide for HP-UX, MPE/iX
and Microsoft Windows NT
Users and Service Manual
Control Panel Quick Reference Card
These documents are located on the following external web page:
http://www.hp.com/essd/model12H_alldocs.html
NOTE
The ARMserver software will be provided as a patch for MPE/iX 6.5.
AutoRAID Configuration Requirements
Model 12H AutoRAID is supported using firmware revision 56
Controller Mode should be set to Normal
X Controller to be connected to the HP 3000, Y controller unconnected and terminated
Rebuild priority should be set to High
Loginal Unit Number (LUN) (0) must be configured
Host Hardware/Firmware Requirements
Support will only be allowed on a dedicated SCSI bus, with no other types of devices
(homogeneous bus environment).
Daisy chaining of two or more model 12H is supported within the recommended SCSI
configuration.
NOTE
Recommended SCSI Configuration: Maximum of 15 LDEVs per SCSI bus
(Maximum of 8 LDEVs for performance.) Having 9 or more LDEVs configured
will cause performance degeneration under high I/O loads.