APPC Subsystem on MPE/XL Node Manager's Guide (30294-90007)
156 AppendixA
Messages
Logging Messages
54 MESSAGE: APPC: ! ! Limits Failed: TRANSACTION FAILURE
(APPCLOG 54).
CAUSE: Internal error in CNOSTP or COPRTP.
ACTION: Give the internal trace to your HP representative.
55 MESSAGE: APPC: ! ! Limits Failed: SESSION OUTAGE OCCURRED
(APPCLOG 55).
CAUSE: The APPC session ended unexpectedly during a CNOSTP or
COPRTP conversation.
ACTION: Use the APPCCONTROL STATUS command, specifying
STYPE=SNASVCMG, to verify that a CNOS session is active.
56 MESSAGE: APPC: ! ! Limits Failed: NO CNOS SESSION AVAILABLE
(APPCLOG 56).
CAUSE: No sessions are available for the CNOSTP.
ACTION: Restart the APPC subsystem. Issue the APPCCONTROL STATUS
command, specifying STYPE=SNASVCMG, to verify that CNOS sessions
are active.
57 MESSAGE: APPC: ! ! Limits Failed: CHANGE SESSIONS FAILURE
(APPCLOG 57).
CAUSE: Internal APPC subsystem error.
ACTION: Give the internal trace to your HP representative.
58 MESSAGE: APPC: ! ! Limits Failed: RESOURCE FAILURE NO RETRY
(APPCLOG 58).
CAUSE: A CNOSTP or COPRTP conversation failed. The session might
have failed, or the TP on the remote system might have encountered an
error and deallocated the conversation.
ACTION: Reissue the APPCCONTROL SESSIONS command, or restart the
APPC subsystem.
59 MESSAGE: APPC: ! ! Limits Failed: UNKNOWN ERROR
(APPCLOG 59).
CAUSE: An error has occurred in the CNOSTP or COPRTP.
ACTION: Give the APPC subsystem internal trace to your HP
representative.
60 MESSAGE: APPC: Stype=!, Mode=!, Limit=!, Source=!, Target=!
(APPCLOG 60).
CAUSE: A CNOS (Change-Number-Of-Sessions) transaction completed
successfully. This message follows message APPCLOG 49 or
APPCLOG 50 and supplies more information.