cannot be a empty string or a number.
ACTION Please consult the LOGTOOL help facility for the correct syntax of the desired command.
651 ****** REQUIRED "LOG=<LOG RANGE LIST>" PARAMETER WAS NOT FOUND ***( LTERR 651
)
CAUSE The user did not give a mandatory parameter of LOG= in the input text.
ACTION Please consult the LOGTOOL help facility for further information on the command.
652 ****** REQUIRED "FILES=<WORK FILE LIST>" PARAMETER WAS NOT FOUND ***( LTERR 652
)
CAUSE The user did not give a mandatory parameter of FILES= in the input text.
ACTION Please consult the LOGTOOL help facility for further information on the command.
653 ****** REQUIRED "OUTFILE=<WORK FILE NAME>" PARAMETER WAS NOT FOUND ***(
LTERR 653 )
CAUSE The user did not give a mandatory parameter of OUTFILE= in the input text.
ACTION Please consult the LOGTOOL help facility for further information on the command.
655 ****** THE LINE PRINTER IS AN INVALID OUTPUT FILE FOR THIS COMMAND ( LTERR 655 )
CAUSE The user has specified the line printer with the OUTFILE= parameter. But the product of the command is
not a printable file.
ACTION Please consult the LOGTOOL help facility for further information
656 ****** COMMAND NAME EXPECTED. ( LTERR 656 )
CAUSE The first token given on the input text was not a command.
ACTION Please consult the LOGTOOL help facility for a list of commands available within LOGTOOL.
657 ****** REQUIRED "SECONDS=<#SECONDS>" PARAMETER WAS NOT FOUND
***( LTERR 657 )
CAUSE The command given by the user requires a SECONDS= parameter. This parameter indicates the number of
seconds that the operation should be performed, or the number of seconds between operations.
ACTION Please consult the LOGTOOL help facility for further information.
658 ****** REQUIRED "TYPE=<TYPE LIST>" PARAMETER WAS NOT FOUND ( LTERR 658 )
CAUSE The user did not give a mandatory parameter of TYPE= in the input text.
ACTION Please consult the LOGTOOL help facility for further information on the command.
659 ****** REQUIRED "ENABLE=<FIELD LABEL LIST>" OR "DISABLE=<FIELD LABEL LIST>"
PARAMETER WAS NOT FOUND ( LTERR 659 )
CAUSE The user did not give a mandatory parameter of ENABLE= or DISABLE= in the input text.
ACTION Please consult the LOGTOOL help facility for further information on the command.
702 ****** INSUFFICIENT CAPABILITIES TO PERFORM THIS COMMAND ( LTERR 702 )
CAUSE The user does not have a high enough diagnostic security level to execute the requested command.
ACTION Please consult the diagnostic user interface manual for detail concerning diagnostic security levels.
713 ****** FILE ! HAS NO MORE ROOM FOR DATA ( LTERR 713 )
CAUSE The file specified in the OUTFILE= parameter has been filled to capacity.
ACTION Select a smaller set of data to be placed in the outfile.
720 ****** THE LINE PRINTER MAY NOT BE ACCESSED IN APPEND MODE ( LTERR 720 )
CAUSE The user has selected the system printer as the outfile, and also gave the APPEND option. This is not
allowed.