Appendix A 203
Messages
SNACONTROL Error Messages
SNACIERR 45 MESSAGE: CAN’T SPECIFY DEBUG HERE. (SNACIERR 45)
CAUSE: The
DEBUG
parameter was specified in an SNACONTROL
command; none of the commands uses
DEBUG
.
ACTION: Reissue the command without a
DEBUG
parameter.
SNACIERR 46 MESSAGE: SNA SWITCH FROM COMPAT. MODE TO NATIVE MODE
ERROR. (SNACIERR 46)
CAUSE: An internal error has occurred.
ACTION: Write down the circumstances and call your Hewlett-Packard
support contact.
SNACIERR 47 MESSAGE: LINK TRACE SIO REQUEST FAILURE. (SNACIERR 47)
CAUSE: Link-level tracing is already on for the node.
ACTION: None.
CAUSE: An internal error has occurred.
ACTION: Write down the circumstances and call your Hewlett-Packard
support contact.
SNACIERR 48 MESSAGE: LINK TRACE DISABLE REQUEST FAILURE.
(SNACIERR 48)
CAUSE: An internal error has occurred.
ACTION: Write down the circumstances and call your Hewlett-Packard
support contact.
SNACIERR 49 MESSAGE: LINK TRACE FILE OPEN FAILURE. (SNACIERR 49)
CAUSE: An illegal
TraceFile
parameter was specified in an
SNACONTROL START or SNACONTROL TRACEON command.
ACTION: Ensure that the specified
TraceFile
is a valid file name (see
the description of the command you issued).
CAUSE: The user who issued the command might not have the proper
system capabilities.
ACTION: Verify that the user has node manager (NM) capabilities.
CAUSE: A trace manager problem might exist.
ACTION: Write down the circumstances and call your Hewlett-Packard
support contact.
SNACIERR 50 MESSAGE: MAX DATA (PIU) TOO LARGE. (SNACIERR 50)
CAUSE: The value specified in the MAX DATA field of the “SNA Node
Configuration: PU Data” screen is too large.
ACTION: Enter a valid value in the MAX DATA field.
CAUSE: An internal error has occurred.