SCSI-Fibre Channel Router Datasheet

Provides connectivity between SCSI High Voltage Differential (HVD) and Fibre Channel equipment
and vice versa.
• Fibre optic cable: 62- or 50-micron fibre optic cable with dual SC connector, HSSDC Gigabit
Interface Converters (GBIC)
• SCSI-FC Router (host) microcode revision 8.01.0A or later
• SCSI-2 HVD compliant host adapter
• SCSI-2 compliant host
• SCSI-2 compliant cabling
• Proper electrical power source (UPS required for High Availability environments)
• Fabric solution requires one A5814A-003 router. (A5814A is not upgradeable to A5814A-003)
• Fibre optic cable: 62- or 50-micron fibre optic cable with dual SC connector, HSSDC Gigabit
Interface Converters (GBIC)
• SCSI-FC Router (host) microcode revision 7.60 or later
• SCSI-FC Router (device) microcode revision 2.50 or later
• SCSI-2 HVD compliant host adapter
• SCSI-2 compliant host
• SCSI-2 compliant cabling
• Proper electrical power source (UPS required for High Availability environments)
• Extender solution requires two A5814A routers. (A5814A is not upgradeable to A5814A-003)
• MPE/iX 6.0 Express 1, MPE/iX 6.5 and MPE/iX 7.0 Express 1
• HP-UX Operating System 11.0 (Patch Level: SP48)
• Windows NT 4.0 Server (Service Pack 6)
• HP SureStore E Disk Array XP48 (FC connectivity only, uses one A5814A-003 router)
• HP SureStore E Disk Array XP512 (FC connectivity only, uses one A5814A-003 router)
• HP SureStore E Disk Array VA7100 (FC connectivity only, uses one A5814A-003 router)
• HP SureStore E Disk Array XP256 (SCSI connectivity only, uses two A5814A routers)
• HP SureStore E Disk Array 12H (SCSI connectivity only, uses two A5814A routers)
• HP SureStore E Disk System HVD 10 (SCSI connectivity only, uses two A5814A routers)
• DLT 4000, 7000 and 8000 SCSI-2 HVD Tape Libraries(SCSI only, uses two A5814A routers)
External serial port: RJ-11 connector (57K-baud rate)
Operating Temperature: 0C (32F) to 40C (104F)
Storage Temperature: -40C (-40F) to 75C (167F)
Relative Humidity: 10% to 95% non-condensing
Height: 7.62 cm (3 in.)
Width: 10.795 cm (4.25 in.)
Depth: 31.115 cm (12.25 in.)
Weight: 1.8 kg (3.97 lbs.)
Note: The SCSI-FC Router can also be installed into a rackmountable hub enclosure (A5842A).
100-240 VAC; 50-60 Hz; 0.75-0.50 A
LED indicators