NetBase for MPE Reference Guide

Using CONFIG
3-15
STATS - Read-Read Filter (ms)
This parameter is the threshold above which read-read transaction time statistics are captured. If a
read-read response time is less than this value, that particular transaction is ignored for statistics
gathering. The measurement is in milliseconds. A value of 0 disables the filtering. The maximum is
2,147,483,647. This command takes effect when the STATS START command is issued in NBCTRL.
Default = 0
Maximum = 2,147,483,647
STATS - Read-Write Filter (ms)
This parameter is the threshold above which read-write response time statistics are captured. If a
read-write response time is less than this value, that particular response is ignored for statistics
gathering. The measurement is in milliseconds. A value of 0 disables the filtering. The maximum is
2,147,483,647. This command takes effect when the STATS START command is issued in NBCTRL.
Default = 0
Maximum = 2,147,483,647
STATS - Low User Response Filter
This parameter is the threshold above which user response time statistics are captured. If the time
between the start and finish of the terminal read is less than this value, that particular response is
ignored for statistics gathering. The measurement is in milliseconds. A value of 0 disables the
filtering. The maximum is 2,147,483,647. This command takes effect when the STATS START
command is issued in NBCTRL.
Default = 0
Maximum = 2,147,483,647
STATS - High User Response Filter
This parameter is the threshold below which user response time statistics are captured. If the time
between the start and finish of the terminal read is greater than this value, that particular response
is ignored for statistics gathering. The measurement is in milliseconds. A value of 0 disables the
filtering. The maximum is 2,147,483,647. This command takes effect when the STATS START
command is issued in NBCTRL.
Default = 0
Maximum = 2,147,483,647