MPE/iX Intrinsics Reference Manual (32650-90875)

Chapter 9 585
Command Definitions (MAIL-PUTJCW)
PUTJCW
PUTJCW
NM and CM callable.
Assigns the value of a particular job control word (JCW) in the job control word table.
Syntax
CA U16 I16
PUTJCW(
jcwname,jcwvalue,jcwstatus
);
Parameters
jcwname
character array (required)
Passes the name of the JCW. This array can contain up to 255 characters,
beginning with a letter and ending with a nonalphanumeric character,
such as a blank. An @ causes all executing JCWs to be set to
jcwvalue
.
jcwvalue
16-bit unsigned integer by reference (required)
Passes the value of the JCW.
jcwstatus
16-bit signed integer by reference (required)
Returns the execution status:
Value Meaning
0
Successful
1 Error,
jcwname
greater than 255 characters
2 Error,
jcwname
does not start with an alpha character
3 Error, JCW table overflow (no JCW with this name exists
in table and unable to create new entry)
4 Error,
jcwname
cannot be a valid JCW value
5 Error, cannot assign a value to a system-reserved JCW, or
a read-only variable
6 Warning, standard variable reclassified as a JCW
7 Error, cannot reclassify predefined variable
Operation Notes
If a JCW of the same name already exists in the table, only its value is entered. If no entry
exists for this name, an entry is created and its value is entered.
There are three types of JCWs in the system:
User-defined
System-defined