MPE/iX Intrinsics Reference Manual (32650-90875)
Chapter 6 287
Command Definitions (FLUSHLOG-GETUSERMODE)
FWRITE
but the perforation between pages is not automatically skipped. For the
Hewlett-Packard 2608S and 2563A, if auto-eject and feature mode are in
effect, a code of %60 is replaced by two codes of %302, and a code of %55 is
replaced by three codes of %302. The resulting skip is double or triple space
with auto-eject, respectively.
Figure 6-2. Carriage-Control Data
Operation Notes
If information is written to a fixed-length record and the NOBUF
aoption
in FOPEN/HPFOPEN
is not specified, any unused portion of the record is padded with binary zeros or ASCII
blanks.
When the FWRITE intrinsic is executed, the logical record pointer is set to the record
immediately following the record just written, or to the first logical record in the next block
for NOBUF files. If RIO access is used, the modified record is set to the ACTIVE state.
When an FWRITE call writes a record beyond the current logical end-of-file indicator, this
Data output contains
132 characters; the
prefix byte is added
and contains 0.
Data output contains
132 characters.
FOPEN
or
:FILE
Data output contains
132 characters.
Carriage
Control
Foption
or
CCTL
Data output contains
132 characters.
Data output contains 132
characters; the prefix
character added is a car-
riage control character
specified by the FWRITE
control character.
FWRITE Controlcode
Carriage
Control
Foption
not
specified
or
NOCCTL
record = 132
= 0
= 1
= Greater than 1
132
record = 132
132
record = 132
132
record = 132
Byte recsize
1 133
record = 132
recsize
132
record = 132
Byte recsize
1 133
Data output contains
132 characters; the con-
trol character in the first
byte is not printed if out-
put is to a list device.
con
trol
0
Effect on Data Output