MPE/iX Intrinsics Reference Manual (32650-90875)
162 Chapter5
Command Definitions (FCONTROL - FLOCK)
FDEVICECONTROL
69 Suppress Echo of Read Terminator: Valid values are:
1
Enables functionality. Gives an application the ability to
determine whether or not to include the read terminators with
the data that is echoed back to the device. Once echo
suppression is enabled, no read terminating characters will be
echoed to the device until echo suppression is disabled.
0
Disables the functionality.
193/I16V Record processing information for NRJE spoolfiles:
parm1
Indicates the character code (for example, ASCII) of
spoolfile data. Refer to SNA NRJE Network Remote Job
Entry User/Programmer Reference Manual.
parm2
(14:1) 0 = Data not compacted 1 = Data compacted
parm2
(15:1) 0 = Data not compressed 1 = Data compressed
Table 5-1. FDEVICECONTROL Control Code 192 Values
Parm1 Parm2 Description
1 R/W Specify terminal or printer type file
2 R/W Set read timeout value for the next read
3 R/W Set the line speed for the device
4 R/W Set echo ON/OFF at a terminal
5 R/W Set system break response ON/OFF at a terminal
6 R/W Set subsystem break response ON/OFF at a terminal
8 R Obtain time used for completion of the last read
9 R/W Set parity checking ON/OFF
10 R/W Set type of parity to check
11 R/W Set parity generation ON/OFF
12 R/W Set type of parity generated
14 R/W Set line deletion response
15 R/W Set transparent editing mode
26 R/W Device XON/XOFF enable
27 R/W Set XOFF timer value
28 R Block mode types supported