MPE/iX Error Messages Manual Vol 3 (32650-90880)

Chapter 2 91
Error Messages Viii C 2
Measurement Interface
130 MESSAGE The current class has been ENABLED too many
times without intervening DISABLES.
CAUSE Either 1) a second enable for global class, 2) more ID class
enables than total number of device classes or more
LDEVs than exist in given device class, or 3) a change in
groups selected with new enables for new process in
process class.
ACTION Correct misunderstanding in using ENABLE
MEASUREMENTS. See the MPE XL Measurement
Interface User's Guide for more information on using the
procedure ENABLE_MEASUREMENTS.
140 MESSAGE The number of counters do not match the known
number of object classes.
CAUSE User called CONVERT_TO_STD_OBJCL procedure with
group whose group header shows a number of counters to
be not 10, 33, or 501.
ACTION Check to be sure group is an object class group. Modify
input and try again.
150 MESSAGE The group index does not belong to an object
class group.
CAUSE User called CONVERT_TO_STD_OBJCL procedure with
a group that is not recognized as an object class group for
the particular class.
ACTION Check to be sure the group is an object class group. Modify
input and try again.
160 MESSAGE LDEVS in the array are not all of the same
device type.
CAUSE User called ENABLE_MEASUREMENT with an array of
LDEVs that are not of the same device class, or user called
DISABLE_MEASUREMENTS with an array of LDEVs
that are not of the same device class.
ACTION Correct LDEVs in the array to be of the same device class
and retry.
170 MESSAGE Failed to obtain lock for the MEAS_KSO_TABLE.
CAUSE Major problem with MEASUREMENT INTERFACE data
structure or control block lock code of the operating
system.
ACTION Call your Hewlett-Packard Representative.
180 MESSAGE Failed to obtain lock for the PROCESS LOOKUP
SUBCLS TABLE.
CAUSE Major problem with MEASUREMENT INTERFACE data
structure, or control block lock code of the operating