MPE/iX Error Messages Manual Vol 3 (32650-90880)
Chapter 4 191
Error Messages Viii C 3
System Disk Load
ACTION Determine cause of error from LOAD_POST and correct.
315 MESSAGE An error was received from FCLOSE of boot
file.
CAUSE Error from FCLOSE for a boot file.
ACTION Determine cause of error from FCLOSE and correct.
316 MESSAGE The procedure failed to add boot file to the
LIF directory.
CAUSE Error returned from ADD_NEXT_DIR_ENTRY for a boot
file while attempting to add an entry to the LIF directory.
ACTION Determine cause of error from ADD_NEXT_DIR_ENTRY
and correct.
317 MESSAGE There was an error in the number of blocks on
tape for the boot file; file length error.
CAUSE Record count error from tape while reading boot file data.
Invalid tape. Possible tape read error or tape position
error.
ACTION Determine cause of error and correct. Clean tape drive and
retry. Clean tape drive, remake tape and retry.
318 MESSAGE An error was received from RENDEZVOUSIO
reading first label from tape.
CAUSE Error returned from RENDEZVOUSIO for read labels.
First read from the tape. Possible tape read error or tape
position error.
ACTION Determine cause of error from RENDEZVOUSIO and
correct. Clean tape drive and retry. Clean tape drive,
remake tape and retry.
319 MESSAGE An error was received from SENDIO reading the
first label from the tape.
CAUSE Error returned from SENDIO for read labels. First read
from the tape.
ACTION Determine cause of error from SENDIO and correct.
320 MESSAGE An error occurred on the first read; not
enough data read.
CAUSE Tape read expected 256 bytes and got less than 200 bytes.
Possible tape read error or tape position error. First read
from the tape. Reading labels.
ACTION Clean tape drive and retry. Clean tape drive, remake tape
and retry.
321 MESSAGE An error was received from RENDEZVOUSIO
reading the second label from the tape.