MPE/iX Error Messages Manual Vol 3 (32650-90880)

Chapter 4 185
Error Messages Viii C 3
System Disk Load
ACTION Determine cause of error from SENDIO and correct.
264 MESSAGE An error was received from SENDIO writing
sector to save area.
CAUSE Error returned from SENDIO for sparing write sector save
track.
ACTION Determine cause of error from SENDIO and correct.
265 MESSAGE An error was received from SENDIO reading
sector from track save area.
CAUSE Error returned from SENDIO for sparing read sector for
restore track.
ACTION Determine cause of error from SENDIO and correct.
266 MESSAGE An error was received from RENDEZVOUSIO
writing sector to new home.
CAUSE Error returned from RENDEZVOUSIO for sparing write
sector for restore track.
ACTION Determine cause of error from RENDEZVOUSIO and
correct.
267 MESSAGE An error was received from SENDIO writing
sector to new home.
CAUSE Error returned from SENDIO for sparing write sector for
restore track.
ACTION Determine cause of error from SENDIO and correct.
268 MESSAGE This is a bad SECTOR TABLE index error.
CAUSE Internal error. Error in sector state in bad sector table.
ACTION Retry the function (INSTALL, UPDATE, START or mount
volume). Write over sector zero to bypass sparing on this
volume and initialize it again. Call your Hewlett-Packard
Representative.
269 MESSAGE An error was received from SENDIO running
sector test.
CAUSE Error returned from SENDIO for sparing run sector test.
ACTION Determine cause of error from SENDIO and correct.
270 MESSAGE This is an internal error; error in track
start address.
CAUSE Internal debug error. Not released. Invalid sector number
from caller for run track test.
ACTION Call your Hewlett-Packard Representative.
271 MESSAGE An error was received from SENDIO running
track test.