MPE/iX Error Messages Manual Vol 3 (32650-90880)

Chapter 4 177
Error Messages Viii C 3
System Disk Load
ACTION Determine cause of error from DRINIT and correct.
203 MESSAGE An internal file number error occurred upon
trying to get the disk address of a boot
file.
CAUSE File number error while getting disk address. (Internal
error.)
ACTION Call your Hewlett-Packard Representative.
204 MESSAGE An error occurred from file system FFILEINFO
getting the disk address of a boot file.
CAUSE Error returned from FFILEINFO.
ACTION Determine cause of error from FFILEINFO and correct.
205 MESSAGE An error occurred from file system
LM_GET_1ST_EXTENT_INFO getting a disk address
of a boot file.
CAUSE Error returned from LM_GET_1ST_EXTENT_INFO
ACTION Determine cause of error from
LM_GET_1ST_EXTENT_INFO and correct.
206 MESSAGE An error occurred from I/O system reading the
label for a name file from tape for
RENDEZVOUSIO.
CAUSE Error returned by RENDEZVOUSIO reading MPEXLDIR
file label.
ACTION Clean tape drive and retry. Clean tape drive, remake tape
and retry. Determine cause of error from
RENDEZVOUSIO and correct.
207 MESSAGE An error occurred from I/O system reading the
label for a name file from the tape from
SENDIO.
CAUSE Error returned by SENDIO reading MPEXLDIR file label.
ACTION Determine cause of error from SENDIO and correct.
208 MESSAGE An error occurred reading the label for the
name file. Bad tape or wrong tape position;
not enough data read.
CAUSE Error in length of data reading MPEXLDIR file label. Tape
read expected 256 bytes and got less than 200 bytes.
ACTION Clean tape drive and retry. Clean tape drive, remake tape
and retry.
209 MESSAGE An error occurred from I/O system reading the
name file from the tape from RENDEZVOUSIO.
CAUSE Error returned by RENDEZVOUSIO reading MPEXLDIR