MPE/iX Error Messages Manual Vol 3 (32650-90880)

14 Chapter1
Error Messages
Clock/Timers Manager
IN PROGRESS (doing SEND_MSG).
CAUSE Timer interrupt handler has already sent notification
message.
ACTION None needed.
12 MESSAGE The status of the timer entry is non-active.
CAUSE Release of a timer which is dormant.
ACTION None needed.
13 MESSAGE A soft interrupt occurred during pause.
CAUSE Pause received status from extend_receive.
ACTION Pause will retry.
1002 MESSAGE PDC read time of day call returned with an
error; the option is nonexistent.
CAUSE Same as message content.
ACTION Take a system dump.
1003 MESSAGE PDC read time of day call returned with an
error; the time of day is invalid.
CAUSE Clock hardware uninitialized.
ACTION Initialize hardware clock.
1010 MESSAGE PDC read time of day call returned with an
error; the parameter is invalid.
CAUSE Same as message content.
ACTION Take a system dump.
1102 MESSAGE PDC set time of day call returned with an
error; the option is nonexistent.
CAUSE Same as message content.
ACTION Take a system dump.
1103 MESSAGE PDC set time of day call returned with an
error; the time of day is invalid.
CAUSE Same as message content.
ACTION Take a system dump.
1110 MESSAGE PDC set time of day call returned with an
error; the parameter is invalid.
CAUSE Same as message content.
ACTION Take a system dump.
1202 MESSAGE PDC timer call (read calib. and acc.)
returned with an error; the option is