MPE/iX Error Messages Manual Vol 2 (32650-90879)
442 Chapter11
Store/Restore (Native Mode) and TurboSTORE/iX II
(S/R) cont.
726 MESSAGE EXPECTED 'device' FILE SPECIFICATION IN
MOSET. Ex. MOSET=(MO1,MO2). SYNTAX
'MOSET=(device[,..])[,(device[,...])]' (S/R
726)
CAUSE Your MOSET includes invalid device names or ldev
numbers.
ACTION Retype the command and include valid device names or
ldev numbers.
727 MESSAGE MAXIMUM NUMBER OF 'device" SPECIFICATION
EXCEEDED FOR A SERIAL MOSET. Ex.
MOSET=(MO1,MO2,...MOn) EXCEEDS THE MAXIMUM OF
8 (S/R 727)
CAUSE You have included more than 8 devices for MOSET option.
ACTION Retype the command and type valid number of devices
with MOSET option.
728 MESSAGE EXPECTED A ')' TO TERMINATE A SERIAL THE
'MOSET' OPTION. SYNTAX
'MOSET=(device[,..])[,(device[,...])]' (S/R
728)
CAUSE You have not included a ')' to terminate your moset list
after the MOSET option.
ACTION Retype the command and include a ')' to terminate your
moset list.
729 MESSAGE EXPECTED A NAME AS 'device' FILE
SPECIFICATION IN MOSET. NAME AND NUMERIC
DEVICE SPECIFICATIONS CAN NOT BE SPECIFIED
TOGETHER FOR THE MOSET OPTION (S/R 729)
CAUSE Mixing device names and ldev numbers are not allowed
with MOSET option.
ACTION Either use all device names or ldev numbers with the
MOSET option.
730 MESSAGE EXPECTED A NUMBER AS 'device' FILE
SPECIFICATION IN MOSET. NAME AND NUMERIC
DEVICE SPECIFICATIONS CAN NOT BE SPECIFIED
TOGETHER FOR THE MOSET OPTION (S/R 730)
CAUSE Mixing device name and ldev numbers with MOSET
option is not allowed.
ACTION Either use all device names or ldev numbers with the
MOSET option.
731 MESSAGE 'MOSET' OPTION NOT ALLOWED IN SYSGEN/STORE.
(S/R 731)
CAUSE MOSET option is not allowed when STORE command is