374 Chapter9
System Startup, Shutdown, and Configuration (cont)
"Nonclass" Errors
parameter value in the appropriate place.
0004 MESSAGE **error** parameter name is too long
CAUSE The parameter string is too long. Most character strings
are limited to eight alphanumeric characters. Exceptions
include logical and physical manager names, volume
names, and some identification names.
ACTION check parameter name limitations under the appropriate
command and configurator in this manual and/or against
system default values. Enter a parameter name that does
not exceed the maximum length.
0005 MESSAGE **error** too many classnames are specified
CAUSE The maximum number of classnames is eight.
ACTION Enter no more than eight class names.
0006 MESSAGE **error** volume name is too long
CAUSE The name entered to add a volume or to modify the
existing name through the AVOL or MVOL command is too
long. The message can also appear as volume too long.
ACTION Enter a volume name of up to 32 characters.
0007 MESSAGE **error** beginning ldev is larger than
ending ldev
CAUSE The numbers entered in the range command have been
reversed or entered incorrectly. The beginning device
number is larger than the ending number. For example,
LDEV 100/20 instead of LDEV 20/100 or LDEV 10/20
generates this message.
ACTION Begin the range entry with the smallest LDEV number or
the beginning and ending numbers.
0008 MESSAGE **error** missing ending ldev
CAUSE The ending LDEV number has been omitted from the
range specification, for example, LD 10/ or LD
(1/,20,22).
ACTION Reenter the range specification.
0009 MESSAGE **error** product ID is too long
CAUSE The product identification string for the path or device ID=
parameter is too long. Usually an entry mistake.
ACTION Reenter the product identification or check the
IODFAULT.PUB.SYS listing for the existing product
identification string.
0010 MESSAGE **error** io path is too long
CAUSE The iopath entry exceeds the requirement or is of a level