MPE/iX Error Messages Manual Vol 2 (32650-90879)

368 Chapter9
System Startup, Shutdown, and Configuration (cont)
"Nonclass" Errors
CAUSE SYSGEN cannot find the file name entered for the FILE=
parameter. check any additional file system error
messages.
ACTION As the file name entry is probably misspelled or references
a file that does not exist in the group and/or account,
reenter a valid file name.
0052 MESSAGE **error** duplicate filename (sysfile) --!
0053 MESSAGE **error** duplicate filename (io) --!
0061 MESSAGE **error** duplicate system filename (sysfile)
--!
0062 MESSAGE **error** duplicate system filename (io) --!
0063 MESSAGE (CIERR !)
0070 MESSAGE HOLD is invalid here. Use KEEP to permanently
save your changes.
CAUSE You have entered a HOLD command as an outer block
(main menu) command.
ACTION If you want to make additional changes, use a configurator
command. If you want to save the changes as is, use the
KEEP command.
1000 MESSAGE **error** missing !
CAUSE Usually, missing option. Something required for the
command entry is missing.
ACTION Refer to the reference for the action to take.
1001 MESSAGE **error** The first letter of a ! cannot be a
number
CAUSE Usually, the first letter of an LDEV cannot be a number.
Any parameter that requires a character string can
generate this message. This is usually caused by
specifying a parameter value in the wrong position, or is a
trying mistake.
ACTION Refer to the reference for the action to take. If necessary,
use the HELP command to display the syntax and
positional parameters.
1002 MESSAGE **error** ! too long
CAUSE Normally, the entered character string value for the
parameter exceeds the maximum number of characters.
ACTION Use SHOW to display minimum and maximum values (or
characters) for the parameter, or use the HELP command
to display the parameter requirements.
1003 MESSAGE **error** Can't supply a lockword with wild