MPE/iX Error Messages Manual Vol 2 (32650-90879)

364 Chapter9
System Startup, Shutdown, and Configuration (cont)
"Nonclass" Errors
1005 MESSAGE **error** Unnumbered line found in numbered
input.
1016 MESSAGE **error** couldn't save configuration files!
!
CAUSE This message occurs when an error prevents KEEP
execution from saving the temporary configuration data
file information to a permanent file set.
ACTION Refer to preceding SYSGEN errors and possibly file
system errors for action to take.
1022 MESSAGE **error** unexpected end of file on default
file
1023 MESSAGE **error** SYSGEN terminates in initialization
CAUSE This message occurs when the SYSGEN utility aborts
abnormally upon encountering an error in the CI
specification or while attempting to access a configurator
or execute a configurator command. You are returned to
the command interpreter.
ACTION Refer to preceding SYSGEN errors and possibly file
system errors for the action to take.
1029 MESSAGE **error** base group not changed!
CAUSE This message occurs when SYSGEN, for whatever reason,
cannot replace the basegroup with the group you enter in
the BASEGROUP command.
ACTION Refer to preceding SYSGEN errors and possibly file
system errors for the action to take.
1030 MESSAGE **error** group "!" does not exist
CAUSE This message occurs when you reference a basegroup that
does not exit, such as when trying to replace the existing
basegroup with a group that does not exist in the SYS
account.
ACTION You have probably misspelled the group name. Reenter
the name.
1031 MESSAGE **error** Couldn't get start group name
CAUSE Couldn't get name from OS. Internal error shouldn't
happen.
ACTION Contact the software personnel responsible for
maintaining system files.
1033 MESSAGE **error** Start group name ! too long for
SYSGEN
CAUSE The start group name from OS is too long for SYSGEN.
Internal error shouldn't happen.