MPE/iX Error Messages Manual Vol 2 (32650-90879)

358 Chapter9
System Startup, Shutdown, and Configuration (cont)
"Nonclass" Errors
1013 MESSAGE **error** Can't free extra data segment for
rin table
CAUSE SYSGEN has encountered a system error in trying to
release a portion of the RIN table in trying to process your
command.
ACTION Refer to the system error for the action.
1014 MESSAGE **error** Can't get rin table size from extra
data segment
CAUSE SYSGEN has encountered as error in trying to obtain the
RIN table size while processing your command.
ACTION Refer to the system error for action.
1020 MESSAGE **error** can't write MISC configuration data
CAUSE SYSGEN has encountered an error while trying to write to
the miscellaneous configuration data file.
ACTION Refer to the system or file systems error for action.
1021 MESSAGE **error** Only the factory can change this.
CAUSE You have attempted to change an item in the
miscellaneous configuration data that is reserved for
factory maintenance.
ACTION None.
1025 MESSAGE **error** sysprompt string in MISC
configuration corrupt!
CAUSE SYSGEN has encountered an error in trying to obtain the
system prompt string value.
ACTION Contact software personnel responsible for updating and
maintaining these files.
1026 MESSAGE **error** ciprompt string in MISC
configuration corrupt!
1030 MESSAGE **error** configuration files incompatable
with this version of SYSGEN
1031 MESSAGE SYSGEN version = ! Config files version = !
Logging (LOG) Configurator Messages
0500 MESSAGE **warning** of logging processes is smaller
than LID table.
CAUSE Reducing the value of
nlogprocs
below what is currently
used the LID table to be rebuilt from scratch, losing any
current logging IDs (only effect if UPDATE CONFIG or
INSTALL done with tape made from this config).
ACTION If you want logging IDs preserved, raise the value.