MPE/iX Error Messages Manual Vol 2 (32650-90879)

Chapter 9 341
System Startup, Shutdown, and Configuration (cont)
"Nonclass" Errors
console
CAUSE The LDEV you chose to add through the ADEV or AVOL
command or use as a new device number in the MDEV or
MVOL command is the LDEV reserved for the system
console.
ACTION Chose another unassigned LDEV for adding or modifying a
local device or volume.
1008 MESSAGE **error** ldev is already assigned to
configured volume
CAUSE The LDEV you chose to add through the AVOL command or
use as a new device in the MVOL command is already
assigned to a configured volume.
ACTION Chose another unassigned LDEV for the new or modified
volume.
1009 MESSAGE **error** can't read Ioldev configuration
file
CAUSE SYSGEN cannot read the configuration data file IOLDEVP.
The program terminates.
ACTION Refer to the file system error for action to take.
1010 MESSAGE **error** can't read Ioclass configuration
file
CAUSE SYSGEN cannot read the configuration data file
IOCLASSP. The program terminates.
ACTION Refer to the file system error for action to take.
1011 MESSAGE **error** can't reset Ioldev file
1012 MESSAGE **error** can't reset Ioclass file
1013 MESSAGE **error** can't reset Iovolume file
1015 MESSAGE **error** A device can only have ! volume
classes.
CAUSE Too many volume classes have been assigned to a volume
through the CLASS= parameter.
ACTION Limit the number of volume classes to the number that
appears in the message.
1016 MESSAGE **error** A device can only have ! classes.
CAUSE Too many classes have been assigned to an LDEV through
the CLASS= parameter.
ACTION Limit the number of classes to the number that appears in
the message.
1017 MESSAGE **error** can't write to Ioldev configuration