MPE/iX Error Messages Manual Vol 2 (32650-90879)

Chapter 9 327
System Startup, Shutdown, and Configuration (cont)
Class Errors
ACTION See NOTE at the end of the ISL error messages.
CE22 MESSAGE Utility file header inconsistent: pdc_cache
entry. (E)
CAUSE Firmware error.
ACTION Contact CE.
CE23 MESSAGE Internal inconsistency: iodc_entry_init -
FATAL! (E)
CAUSE Firmware error.
ACTION Contact your Hewlett-Packard Support Representative.
CE24 MESSAGE Internal inconsistency: iodc_entry_init -
console - FATAL! (E)
CAUSE Firmware error.
ACTION Contact your Hewlett-Packard Support Representative.
CE25 MESSAGE Internal inconsistency: iodc_entry_init -
boot device - FATAL! (E)
CAUSE Firmware error.
ACTION Contact your Hewlett-Packard Support Representative.
CE26 MESSAGE Utility file header inconsistent: Bad aux_id.
(W)
CAUSE ISL cannot read the file header auxiliary ID.
ACTION See NOTE at the end of the ISL error messages.
CE27 MESSAGE Bad utility file type. (W)
CAUSE Proper file entry does not exist.
ACTION See NOTE at the end of the ISL error messages.
NOTE
Codes CE07, 16, 17, 19, 1C, 21, and 26 indicate an error with the utility. A
different utility may be booted. For the same utility to be booted, you must
update it from a system master tape set or a system load tape created by the
SYSGEN utility. Code CE27 does not necessarily indicate an error. The name
typed in may match a name in the directory which is not a bootable file.