MPE/iX Error Messages Manual Vol 2 (32650-90879)
316 Chapter9
System Startup, Shutdown, and Configuration (cont)
Class Errors
Class Errors
Class Error A: Boot Path Test
Boot device related errors and/or channel I/O errors take the following multiplexed code
form:
01wx
Ayzz
where:
w = CIO slot number (<> C)
x = Device address (always 0 for the console)
y = CIO mid-bus slot number
zz = IODC driver error code 00 - 7F.
0100 Ay80 MESSAGE Boot Error: First display.
Boot Error: Second display.
Boot from Primary Path (Y or N)?>
CAUSE IODC load from the CIO channel in console path fails.
ACTION Check that the tape drive is functional. (Check switch
setting if switch selector is used.) Recable new drive. If
measures fail, contact your Hewlett-Packard Support
Representative and boot from primary path if possible.
0100 AyF0 MESSAGE Boot Error: First display.
Boot Error: Second display.
Boot from Primary Path (Y or N)?>
CAUSE LIF volume label error occurs. The media may have been
improperly initialized.
ACTION Check that the tape drive is functional. (check switch
setting, if switch selector is used.) check that the mounted
tape is a boot tape. Recable new drive or replace suspect
tape. If measures fail, contact your Hewlett-Packard
Support Representative and boot from primary path if
possible.
01wx AyF8 MESSAGE Boot Error: First display.
Boot Error: Second display.
Boot from Primary Path (Y or N)?>
CAUSE IPL checksum fails. The utility (or ISL) being read from
tape is possibly corrupted.
ACTION Try using the utility from another tape, such as from the
master backup. If problem persists, contact your