MPE/iX Error Messages Manual Vol 2 (32650-90879)

308 Chapter8
System Startup, Shutdown, and Configuration
Class Errors
06 MESSAGE No message. System halts. (E)
CAUSE Cannot verify memory with all zeros.
ACTION Contact your Hewlett-Packard Support Representative.
07 MESSAGE No message. System halts. (E)
CAUSE Pattern testing of external interrupt enable mask register
fails.
ACTION Contact your Hewlett-Packard Support Representative.
08 MESSAGE No message. System halts. (E)
CAUSE Cannot set interrupt register to zero.
ACTION Contact your Hewlett-Packard Support Representative.
09 MESSAGE No message. System halts. (E)
CAUSE Pattern testing of interrupt register fails.
ACTION Contact your Hewlett-Packard Support Representative.
0A MESSAGE No message. System halts. (E)
CAUSE Pattern testing of chain RAM base register fails.
ACTION Contact your Hewlett-Packard Support Representative.
0B MESSAGE No message. System halts. (E)
CAUSE Failure encountered while pattern testing mask register.
ACTION Contact your Hewlett-Packard Support Representative.
0E MESSAGE No message. System halts. (E)
CAUSE Pattern testing of reset address register fails.
ACTION Contact your Hewlett-Packard Support Representative.
0F MESSAGE No message. System halts. (E)
CAUSE Pattern testing of reset data register fails.
ACTION Contact your Hewlett-Packard Support Representative.
10 MESSAGE No message. System halts. (E)
CAUSE Reset does not clear soft physical address (SPA).
ACTION Contact your Hewlett-Packard Support Representative.
11 MESSAGE No message. System halts. (E)
CAUSE Either a channel I/O card is not installed, or none of the
CIO cards pass the self-test and are ready for command.
ACTION Contact your Hewlett-Packard Support Representative.
12 MESSAGE No message. System halts. (E)
CAUSE Stop command does not set the ready (RDY) bit.