MPE/iX Error Messages Manual Vol 2 (32650-90879)

Chapter 8 301
System Startup, Shutdown, and Configuration
Class Errors
is attempted. This should cause a reserved operation trap.
ACTION Contact your Hewlett-Packard Support Representative.
Remove the floating-point board, then reboot the system.
0F MESSAGE No message. System halts. (E)
CAUSE An error occurs as a coprocessor load from an I/O address
is attempted. This load should abort.
ACTION Contact your Hewlett-Packard Support Representative.
31 MESSAGE No message. System halts. (E)
CAUSE Test results in an unexpected assist exception trap. This
cause can stem from a variety of problems in the system,
possibly resulting from a test of the conflict comparator.
This test can also reflect a malfunction of one or more of
the math chips.
ACTION Contact your Hewlett-Packard Support Representative.
Remove the floating-point board, then reboot the system.
42 MESSAGE No message. System halts. (E)
CAUSE Test of ALUZERO condition fails.
ACTION Contact your Hewlett-Packard Support Representative.
Remove the floating-point board, then reboot the system.
43 MESSAGE No message. System halts. (E)
CAUSE Test of ALUZERO condition fails.
ACTION Contact your Hewlett-Packard Support Representative.
Remove the floating-point board, then reboot the system.
44 MESSAGE No message. System halts. (E)
CAUSE Test of ALUSIGN condition fails.
ACTION Contact your Hewlett-Packard Support Representative.
Remove the floating-point board, then reboot the system.
45 MESSAGE No message. System halts. (E)
CAUSE Test of XOR in ALU fails.
ACTION Contact your Hewlett-Packard Support Representative.
Remove the floating-point board, then reboot the system.
46 MESSAGE No message. System halts. (E)
CAUSE Test of AND in ALU fails.
ACTION Contact your Hewlett-Packard Support Representative.
Remove the floating-point board, then reboot the system.
47 MESSAGE No message. System halts. (E)
CAUSE Test of OR in ALU fails.