MPE/iX Error Messages Manual Vol 2 (32650-90879)

Chapter 8 297
System Startup, Shutdown, and Configuration
Class Errors
Class Error 3: System Monitor Card Failure
System monitor card messages take the form:
30xx
where:
xx = detailed error number.
00 MESSAGE No message. System halts. (E)
CAUSE Undefined error occurs at the start of the test of this
board.
ACTION Contact your Hewlett-Packard Support Representative.
01 MESSAGE No message. System halts. (E)
CAUSE data error occurs while verifying byte 10c (hex) of
nonvolatile memory (NVM).
ACTION Contact your Hewlett-Packard Support Representative.
02 MESSAGE No message. System halts. (E)
CAUSE General register 0 is not zero at transfer of control (TOC).
ACTION Contact your Hewlett-Packard Support Representative.
03 MESSAGE No message. System halts. (E)
CAUSE Invalid return address received for TOC. Second possible
cause of the error is memory.
ACTION Contact your Hewlett-Packard Support Representative.
07 MESSAGE No message. System halts. (E)
CAUSE Cannot verify processor dependent code (PDC) PROM. No
PDC PROM installed.
ACTION Contact your Hewlett-Packard Support Representative.
08 MESSAGE No message. System halts. (E)
CAUSE Cannot find second part of self-test in PDC PROM. PDC
PROM not installed.
ACTION Contact your Hewlett-Packard Support Representative.
09 MESSAGE No message. System halts. (E)
CAUSE Cannot find PDC code in PDC PROM.
ACTION check PDC PROM. Contact your Hewlett-Packard Support
Representative.
0A MESSAGE No message. System halts. (E)
CAUSE Cannot initialize memory with switch 3 open.