MPE/iX Error Messages Manual Vol 2 (32650-90879)

294 Chapter8
System Startup, Shutdown, and Configuration
Class Errors
CAUSE Verification of the parity error generator on byte zero fails.
Second possible cause of the error is memory.
ACTION Contact your Hewlett-Packard Support Representative.
0B MESSAGE No message. System halts. (E)
CAUSE Verification of the parity error generator on byte one fails.
Second possible cause of the error is memory.
ACTION Contact your Hewlett-Packard Support Representative.
0C MESSAGE No message. System halts. (E)
CAUSE Verification of the parity error generator on byte two fails.
Second possible cause of the error is memory.
ACTION Contact your Hewlett-Packard Support Representative.
0D MESSAGE No message. System halts. (E)
CAUSE Verification of the parity error generator on byte three
fails. Second possible cause of the error is memory.
ACTION Contact your Hewlett-Packard Support Representative.
0F MESSAGE No message. System halts. (E)
CAUSE cache diagnostic register bit is stuck.
ACTION Remove floating-point board, then reboot the system.
Contact your Hewlett-Packard Support Representative.
10 MESSAGE No message. System halts. (E)
CAUSE Failure while verifying data path on the instruction cache.
Second possible cause of error is the execution unit..
ACTION Contact your Hewlett-Packard Support Representative.
15 MESSAGE No message. System halts. (E)
CAUSE Size of I_CA and D_CA do not match (check revision of
execution unit.) Second possible cause of the error is the
execution unit.
ACTION Contact your Hewlett-Packard Support Representative.
16 MESSAGE No message. System halts. (E)
CAUSE Cache line gets updated on data TLB MISS fault.
ACTION Contact your Hewlett-Packard Support Representative.
17 MESSAGE No message. System halts. (E)
CAUSE Memory line gets updated on data TLB MISS fault.
ACTION Contact your Hewlett-Packard Support Representative.
18 MESSAGE No message. System halts. (E)
CAUSE Failure while verifying byte transaction with data cache