MPE/iX Error Messages Manual Vol 2 (32650-90879)

Chapter 8 291
System Startup, Shutdown, and Configuration
Class Errors
28 MESSAGE No message. System halts. (E)
CAUSE Verification of the memory protection trap with word
access fails.
ACTION Contact your Hewlett-Packard Support Representative.
29 MESSAGE No message. System halts. (E)
CAUSE Verification of the instruction TLB MISS fault fails.
ACTION Contact your Hewlett-Packard Support Representative.
2A MESSAGE No message. System halts. (E)
CAUSE Cannot force data TLB MISS fault.
ACTION Contact your Hewlett-Packard Support Representative.
2B MESSAGE No message. System halts. (E)
CAUSE Cannot verify protection ID, access ID.
ACTION Contact your Hewlett-Packard Support Representative.
2C MESSAGE No message. System halts. (E)
CAUSE Cannot verify public pages.
ACTION Contact your Hewlett-Packard Support Representative.
2D MESSAGE No message. System halts. (E)
CAUSE Cannot distinguish between instruction CA and data CA
with the diagnostic register.
ACTION Contact your Hewlett-Packard Support Representative.
2E MESSAGE No message. System halts. (E)
CAUSE Verification of the two cycle opcode instruction fails.
Cannot verify TLB FREZ.
ACTION Contact your Hewlett-Packard Support Representative.
31 MESSAGE No message. System halts. (E)
CAUSE Unexpected instruction TLB MISS fault occurs. Second
possible cause of the error is the instruction unit.
ACTION Contact your Hewlett-Packard Support Representative.
32 MESSAGE No message. System halts. (E)
CAUSE Unexpected instruction memory protection trap occurs.
Second possible cause of the error is the instruction unit.
ACTION Contact your Hewlett-Packard Support Representative.
33 MESSAGE No message. System halts. (E)
CAUSE Unexpected TLB MISS trap occurs. Second possible cause
of the error is the instruction unit.
ACTION contact your Hewlett-Packard Support Representative.