MPE/iX Error Messages Manual Vol 2 (32650-90879)
Chapter 8 271
System Startup, Shutdown, and Configuration
Class Errors
ACTION Contact your Hewlett-Packard Support Representative.
07 MESSAGE No message. System halts. (E)
CAUSE Cross-talk occurs between general registers.
ACTION Contact your Hewlett-Packard Support Representative.
08 MESSAGE No message. System halts. (E)
CAUSE Crosstalk occurs among general registers and temporary
registers.
ACTION Contact your Hewlett-Packard Support Representative.
0A MESSAGE No message. System halts. (E)
CAUSE X and B bus bypass testing.
ACTION Contact your Hewlett-Packard Support Representative.
0B MESSAGE No message. System halts. (E)
CAUSE General register 0 bypassed.
ACTION Contact your Hewlett-Packard Support Representative.
0C MESSAGE No message. System halts. (E)
CAUSE General register 0 bypassed on a nullify.
ACTION Contact your Hewlett-Packard Support Representative.
0D MESSAGE No message. System halts. (E)
CAUSE Verification of the trap with interval timer fails.
ACTION Contact your Hewlett-Packard Support Representative.
10 MESSAGE No message. System halts. (E)
CAUSE Interval timer is not incrementing. Second possible cause
of the error may be the execution unit. Third possible
cause of the error also may be the instruction unit.
ACTION Contact your Hewlett-Packard Support Representative.
11 MESSAGE No message. System halts. (E)
CAUSE Interval timer is not causing a trap. Second possible cause
of the error may be the instruction unit. Third possible
cause of the error also may be the translation look-aside
buffer.
ACTION Contact your Hewlett-Packard Support Representative.
12 MESSAGE No message. System halts. (E)
CAUSE Recovery counter is not causing a trap. Second possible
cause of the error may be the instruction unit. Third
possible cause of the error also may be the translation
look-aside buffer.