MPE/iX Error Messages Manual Vol 1 (32650-90878)

38 Chapter2
Command Interpreter
(CIERR)
CAUSE You have included more than one ENV parameter in your
command line; the system is warning you that it is using
the last one named.
ACTION If you do not wish the system to use the last one named in
your command line, reenter the command, omitting the
redundancy.
307 MESSAGE "ENV" HAS NO SUBPARAMETERS, EXPECTED
FILENAME. (CIERR 307)
CAUSE You have entered something that is not an acceptable
subparameter to the ENV parameter. ENV expects only
the name of an environment file.
ACTION Reenter the command, specifying a legitimate
environment file name. To review the command syntax,
invoke the online Help Facility or refer to the MPE/iX
Commands Reference Manual.
308 MESSAGE "OUTQ" PARAMETER OVERRIDES PREVIOUS "OUTQ"
PARAMETER (CIERR 308)
CAUSE You have included more than one OUTQ parameter in
your command line; the system is warning you that it is
using the last one named.
ACTION If you do not wish the system to use the last one named in
your command line, reenter the command, omitting the
redundancy.
309 MESSAGE "OUTQ" NAME MUST BE ALPHANUMERIC. (CIERR 309)
CAUSE You have specified nonnumeric characters in the OUTQ
parameter; this is not allowed.
ACTION Check for syntax or spelling errors and reenter the
command. For more information about the command
syntax, invoke the online Help Facility or refer to the
MPE/iX Commands Reference Manual.
310 MESSAGE "OUTQ" NAME CANNOT EXCEED 8 CHARACTERS.
(CIERR 310)
CAUSE You have specified an OUTQ name that is longer than
eight characters; this is not allowed.
ACTION Reenter your command, specifying an OUTQ name of
eight or fewer characters.
311 MESSAGE "OUTQ" NAME MUST BEGIN WITH AN ALPHABETIC
CHARACTER (CIERR 311)
CAUSE You have used a nonalphabetic character as the first
character of the OUTQ name; this is not allowed.
ACTION Check for syntax or spelling errors and reenter the
command. For more information about the command