MPE/iX Error Messages Manual Vol 1 (32650-90878)

Chapter 4 329
Error Messages V i C 4
(Subsystem 121)
A REJECT error occurred; could be cabling.
CAUSE CS80 transaction was incorrect.
ACTION Verify that cabling is correct and call your support
representative.
251 MESSAGE The error bit in the CS80 hardware status is
set, which indicates that the value in the
ADDRESS field in the CS80 Command is illegal.
A REJECT error occurred; could be cabling.
CAUSE CS80 transaction was incorrect. The medium address
range was exceeded.
ACTION Verify that cabling is correct and call your support
representative.
252 MESSAGE The error bit was set in the CS80 hardware
status was set, which indicates that CS80
Command Volume or Unit is illegal. A REJECT
error occurred; could be cabling.
CAUSE CS80 protocol wasincorrect. The device address range was
exceeded.
ACTION Verify that cabling is correct and call your support
representative.
253 MESSAGE The error bit in the CS80 hardware status was
set, which indicates that the OPCODE of the
CS80 Command bytes is invalid. A REJECT error
occurred; could be
cabling.
CAUSE CS80 command bytes could be invalid.
ACTION Verify that cabling is correct and call your support
representative.
254 MESSAGE The error bit in the CS80 hardware status is
set, which indicates the PARITY of the CS80
Command bytes is bad. A REJECT error
occurred; could be cabling.
CAUSE The device detected a parity error.
ACTION Verify that cabling is correct and call your support
representative.
255 MESSAGE Immediate status returned, indicating the
HOST targeted for this I/O did not respond.
CAUSE Fiber-optic disk detected lack of host communication.
ACTION Verify connection and try again. If problem persists, call
your support representative.