MPE/iX Error Messages Manual Vol 1 (32650-90878)
Chapter 4 327
Error Messages V i C 4
(Subsystem 121)
ACTION Call your support representative.
237 MESSAGE The error bit in the CS80 hardware status was
set, which indicates that the CS80 protocol
requested too many operations at one time.
CAUSE Software problem or cabling problem.
ACTION Call your support representative.
238 MESSAGE The error bit in the CS80 hardware status was
set, which indicates that the device requires
the I/O to be tried again.
CAUSE Device required I/O; usually due to auto head alignment.
ACTION None.
239 MESSAGE The error bit in the CS80 hardware was set,
which indicates the device has had power
re-applied or the heads have re-loaded.
CAUSE Device powered-on; head loaded.
ACTION None.
240 MESSAGE The error bit in the CS80 hardware status was
set, which indicates that the device needs to
align its heads or run internal diagnostics
(RELEASE REQUIRED).
CAUSE Device determined that automatic head alignment was
required; performed same.
ACTION None.
241 MESSAGE The error bit in the CS80 hardware status was
set, which indicates that the diagnostic
frontpanel on the device was accessed
(RELEASE REQUIRED).
CAUSE Device allowed front-panel diagnostics to be executed.
ACTION Determine if front panel was accessed.
242 MESSAGE The error bit in the hardware status was set,
which indicates that the operator unload
button was pushed (RELEASE REQUIRED).
CAUSE Device allowed the operator to spin-down pack.
ACTION Either push button back in, or remove pack.
243 MESSAGE The error bit in the hardware status was set,
which indicates a HARDWARE FAULT detected by
internal diagnostics.
CAUSE Device diagnostics detected hardware problem.
ACTION Call your support representative.