324 Chapter4
Error Messages V i C 4
(Subsystem 121)
ACTION Call your support representative.
214 MESSAGE An error bit in the REJECT field of the CS80
hardware status was set which is undefined.
CAUSE CS80 device status returned invalid information.
ACTION Call your support representative.
215 MESSAGE An invalid unit number was returned in the
CS80 hardware status.
CAUSE CS80 device status returned invalid information.
ACTION Call your support representative.
216 MESSAGE An invalid QSTAT was returned in CS80
hardware status.
CAUSE The QSTAT from device was not defined.
ACTION Call your support representative.
217 MESSAGE The DEVICE ADAPTER MANAGER returned a bad
status in the status field of the DAM Reply
message.
CAUSE Problem in the device adapter level; could be due to a
power failure.
ACTION Monitor the process.
218 MESSAGE Immediate status indicates link protocol or
port event errors occur.
CAUSE Fiber-optic connected disk interface problem. Could be due
to a power failure.
ACTION If problem persists, call your support representative.
219 MESSAGE An incorrect META language was specified
during configuration.
CAUSE Configuration or software version incorrect.
ACTION Call your support representative.
220 MESSAGE An invalid hardware address was specified
during configuration.
CAUSE Configuration of device address incorrect or out of range.
ACTION Examine configuration files.
221 MESSAGE The disk driver has an internal data
structure error.
CAUSE Critical software resource problem.
ACTION Take a system dump. Call your support representative.
222 MESSAGE The INTERNAL TABLE is inconsistent.