VERSION Parameter
This parameter specifies the version of the System Dictionary domain, and has the format:
VERSION = <version name>
If you specify a blank as the value of this parameter, or enter no value, the latest test version (the default
value for this parameter) will be selected.
OPEN-MODE Parameter
This parameter specifies the update mode for System Dictionary, and has the following format:
OPEN-MODE = SHARED-UPDATE or EXCLUSIVE-UPDATE
The default value for the parameter is SHARED-UPDATE.
NAME-MODE Parameter
This parameter specifies whether the internal or external names will be used, and has the following
format:
NAME-MODE = INTERNAL or EXTERNAL
The default is EXTERNAL.
DICT3000 COMMAND
The DICT3000 command is used to specify the Dictionary/V dictionary whose definitions are to be
converted into the System Dictionary format. It also enables you to enter other parameters related to the
definition loading process. It is assumed that the person running SDCONV is the creator of the dictionary.
If this is not the case, the command will fail.
Note that the DICT3000 command will attempt to use defaults for any two of the NAME, PASSWORD, and
OPEN-MODE parameters if they are not specified in the command. In other words, you must actually
specify at least one of the three to open the dictionary. Otherwise, the command will fail. The command
has the following format:
DICT3000 parameter-1meter-2;...parameter-n.
As in the SYSDIC command, the ending period completes the command. The following parameters are
accepted by this command:
NAME Parameter
This parameter specifies the name of the Dictionary/V dictionary whose definitions are to be converted. It
has the format:
NAME = <Dictionary/V dictionary name>
OPEN-MODE Parameter
This parameter is used to specify the Dictionary/V dictionary open mode, and has the following format:
OPEN-MODE = <open mode>
As with the PASSWORD or NAME parameter, this parameter causes any open dictionary to be closed, and
the dictionary with the new open-mode to be opened. The value should be between 1 and 8 as explained in
the TurboIMAGE/V manual. The default for this parameter is 8.
SCOPE-OWNER Parameter
When loading Dictionary/V definitions into the System Dictionary, a number of items may be mapped into